1000w golden gear box gearbox bldc motor kit kiti high rpm in agriculture bd

Aperçu

Détails rapides

Lieu d'origine :

Zhejiang, Chine

Nom de marque :

EPT

Numéro de modèle :

VOL- IEC112S2250-6P

Usage:

Boat, Car, Electric Bicycle, Fan, Home Appliance, Shell Eco-marathon Competition Car

Certification :

CCC, CE, ROHS, UL

Taper:

brushless DC motor

Couple :

21.48Nm

Construction:

Aimant permanent

Commutation:

Brushless

Fonction de protection :

Étanche

Vitesse (tr/min) :

1000rpm

Courant continu (A) :

6.42A

Efficacité:

IE 4

Logement:

Aluminum Frame

Speed Range:

1000rpm

Matériel:

Permanent Magnets

Controller:

Customized, Optional

Braker:

Facultatif

Insulation Class:

Class F

Enclosure:

IP54

Poles:

6P

Wire:

100% copper

Duty:

S1 (continuous)

Capacité d'approvisionnement

Capacité d'approvisionnement :
10000 Unit/Units per Month

Emballage et livraison

Détails de l'emballage
low noise 6 Poles 3HP 1000rpm IEC Brushless dc motor Packing: Standard sea or air package will be perfectly protected in the delivery.
Port
FOB Ningbo

Personnalisation en ligne

Présentation du produit

Motor type Output Power Tension Load Speed Rated Torque Efficacité Noise IP Class
KW V UN tr/min Nm % dB
VOL- IEC90S2250-2P 2.25 220 ac 6.42 3000 7.16 92 62 IP 54
VOL- IEC100S2250-4P 2.25 220 ac 6.42 1500 14.33 92 62 IP 54
VOL- IEC112S2250-6P 2.25 220 ac 6.42 1000 21.48 92 62 IP 54
VOL- IEC112S3750-2P 3.75 220 ac 10.70 3000 11.94 92.5 62 IP 54
VOL- IEC112S3750-4P 3.75 220 ac 10.70 1500 23.88 92.5 62 IP 54

VIEW MORE PLS CONTACT US >>>

Autres produits

Flux de processus

About Us

Packing&Transport

Q :Motor has been running then fails to start,what to do?
UN:Likely cause: Fuse or circuit breaker is tripped.

What to do: Replace the fuse or reset the breaker.

Likely cause: Armature is shorted. Motor may make a humming noise and the circuit breaker or fuse will trip.
What to do: Disassemble motor and inspect the armature for a burnt coil. Inspect the commutator for burnt bars. If this condition exists, the motor needs to be replaced.

Likely cause: The brushes may be worn down too far and no longer make contact with the commutator.
What to do: Check the brushes to make sure that they are still making contact with the commutator. Contact manufacturer for brushes.

Likely cause: Controller may be defective.
What to do: Verify voltage is coming out of the controller.

Q :On initial installation, motor fails to start up,what to do?
UN:Likely cause: Motor is incorrectly wired
What to do: Verify that the motor is wired correctly.

Likely cause: No output power from controller.
What to do: Measure voltage coming from the controller.

Likely cause: Motor is damaged and the armature is rubbing against the magnets.
What to do: Disassemble motor and see if the armature can be realigned by reassembly. Motor may have to be replaced.

Q : Motor takes too long to accelerate,what to do?
UN: Likely cause: Motor controller not properly set.
What to do: Adjust the acceleration trim pot of the controller.

Likely cause: Brushes are worn.
What to do: Verify brush length.

Likely cause: Bearings may be defective.
What to do: Inspect bearings. Noisy or rough bearings should be replaced.

Q : Motor runs in the wrong direction,what to do?
UN: Likely cause: Incorrect wiring
What to do: Interchange the two motor leads.

Q : Motor runs OK but has a clicking noise,what to do?
UN: Likely cause: Suspect a burr on the commutator.
What to do: Remove burr from commutator using a commutator stone.

boîte de vitesses agricole